Check: Air supply circuit

RELAY II · Repair procedures · TURBO DIESEL DW10TD SINCE DATE 17000001 · Checks · Reference B1HD1JP0

1. Recommended tools Figure : e5-p09ec [1] vacuum-pressure manual pump FACOM DA 16. 2. Check Figure : b1hp1fgc Connect the tool [1] on the take-off at "a" (vacuum pump tube). Start the engine. The vacuum value should be 0,8 bar at idle speed.

Open in the interactive documentation