Removing - refitting: Anti-frosting thermostat-Fan resistor-Relay
RELAY · Repair procedures · TWIN AIR CONDITIONNING · Removal-fitting · Reference C5HG1EP0
1. Anti-frosting thermostat 1.1. Removing Figure : c5gp05hc Remove : The bolts (1) The grille Figure : c5hp110c Disconnect the connectors (3). Remove bolts (4). Disengage the bulb (2) (towards the top). Remove the anti-frosting thermostat (5). 1.2. Refitting Proceed in the reverse order to removal…