Removing - refitting: Filter gauze,4HP14 automatic gearbox

XANTIA · Repair procedures · BVA 4HP14 AND BVA4 · Removal-fitting · Reference B2CG03P0

1. Removing Figure : b2cp016c Remove : The oil sump (see the relevant operation) The strainer housing The strainer 2. Refitting Figure : b2cp017c Lubricate and install a new seal. Figure : b2cp018c Fit a new O-ring (3) to the gauze. Figure : b2cp019c Fit the gauze-casing assembly to the hydraulic…