Checks and adjustments: input shaft

XANTIA · Repair procedures · HP20 (AG) AND BVA4 AND INJECTION ES9J4 · Adjustments check · Reference B2CE0BP0

1. Recommended tools Figure : e5ap06hc [1] dial gauge support (-).0337 S. Figure : e5-p14sc [2] dial gauge (-).0337 H. 2. Check Figure : b2cp26wc Fit tools [1] and [2] onto the primary shaft. Measure the clearance after traction and compression. The clearance should be 0,20 ± 0,10 mm. 3. Adjustment…