Switching off: Power circuit
AX · Repair procedures · ELECTRIC MOTOR SA13 · Precautions to be taken · Reference E2-K06P0
ESSENTIAL : With the charging lead disconnected, switch off and wait 30 seconds after the water pump has stopped. 1. Switching off 1.1. Upper battery pack Figure : e2-p011c Figure : d6-p02dc Remove : Fuse (1) The circuit breaker (2) 1.2. Lower battery pack Put the vehicle on a hoist. Figure…