1. Removing ESSENTIAL : With the charging lead disconnected, switch off and wait 30 seconds after the water pump has stopped. Figure : d6-p02rc Remove the bar (1) by pulling it upward. Disconnect the battery negative terminal 12V. Figure : d6-p02sc Disconnect the connector (2) . Remove the 6 bolts…