Removing - refitting: Vacuum pump pressure switch

AX · Repair procedures · ELECTRIC MOTOR SA13 · Removal-fitting · Reference B3FG11P0

1. Removing Figure : b3fp04wc Disconnect the connector (2) . Uncouple the pipe (1). Remove : The (3) bolt The sensor (4) 2. Refitting Put the sensor (4) back into place. Fit and tighten the bolt (3). Couple the pipe (1). Re-connect the connector (2) .