Removing - refitting: heater matrix
XSARA · Repair procedures · REGULAR AIR CONDITIONNING · Removal-fitting · Reference C5HG0TP0
1. Removing Remove : The fascia The heater unit Figure : c5hp07hc Release the clips (1) and (3). Remove the heater matrix (2). 2. Refitting Proceed in the reverse order to removal. N.B. : Fit 2 soft material screws (4) if the clips (1) and (3) are broken.