Removing - refitting: vacuum pump

XSARA · Repair procedures · Removal-fitting · Reference B3FG25P0

1. Removing Figure : b3fp076c Disconnect the vacuum connection (1). Remove : The bolts The nut The vacuum pump 2. Refitting Figure : b3fp077c Fit new o-rings. Clean the joint faces. Refit : The vacuum pump The bolts : Tightening torque to 2.5 da.Nm The nut : Tightening torque to 2.5 da.Nm Reconnect…