Removing-Refitting: Coolant outlet housing/thermostat

C-ELYSEE · Repair procedures · EC5 INJECTION · Removal-fitting · Reference B1GG01FQP0

ESSENTIAL : Observe the safety and cleanliness recommendations. 1. Removing Disconnect the ancillaries battery. Remove : The engine style cover The air filter housing assembly Drain the engine cooling circuit. 2. Coolant outlet housing (Plastic) 2.1. Removing Figure : b1gg197d Remove the bolts (1)…