Removing-refitting: Variable timing electrovalve

C4 PICASSO (B78) · Repair procedures · EP6CDT INJECTION · Removal-fitting · Reference B1EG0125P0

ESSENTIAL : Observe the safety and cleanliness recommendations. 1. Location Figure : b1bg29fd (1) Variable timing electrovalve . 2. Removing Disconnect the ancillaries battery. Figure : b1hg0ked Disconnect the connector (at "a"). Loosen the clips (2) and (4). Remove : The bolts (5) The intermediate…